previous Ordinance Article

 
   
American Ranch Sanitary District

Ordinance Article X

 

 

ARTICLE X

Ordinance Table A

 

Section 1001 - Ordinance Table A Definition

            The Ordinance Table A is a list of commonly known user classes and fixture uses. Each user class has an assigned fixture use.  The fixture use includes strength and flow that are typically based on an industry-wide average and/or actual water flow figures with strengths added. The fixture uses listed for each user class in Ordinance Table A shall be utilized in calculating average and maximum daily flows.

 

Section 1002 - Ordinance Table A Formula

            Fixture use multiplied times the number of fixtures.          

 

Section 1003 - Ordinance Table A


 

Type of Fixture

 

Fixture Units

 

 

 

Res

Com

Bar Sink

1

2

Bathtub (without shower)

2

4

Bathtub (with shower)

3

5

Dental Unit or cuspidor

1

1

Drinking Fountain (each head)

1

1

Laundry Tub

 

2

4

Clothes Washer

 

2

4

Jumbo Clothes Washer

6

5

Jacuzzi type tub

12

18

Lavatory (dental)

 

1

1

Shower (each head)

 

2

4

Kitchen Sink

 

2

4

Dishwasher

 

2

4

Sink (flushing rim, clinic)

10

10

Sink (janitor)

 

2

2

Sink (washup, circular spray)

4

4

Sink (lavatory)

 

1

2

Urinal (pedestal or similar type)

10

10

Urinal (stall or wall)

 

5

5

Urinal (flush tank )

 

3

3

Water closet (flush tank)

3

5

Water closet (flushometer valve)

10

10

Floor drain/sink 2", 3", 4"

4

4

 


 
Ordinance End

 

* * *

Ordinances are subject to change.

Amendments may be considered at a public hearing

by the Board of Directors as necessary. 

Contact the District office to confirm Ordinance requirements.

 

* * *